CHVE75TS3 Millipore Express® SHR Cartridge Filter 5 in. 0.5/0.1 µm Code 7 Silicone

View Products on Sigmaaldrich.com
CHVE75TS3
3  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information

      Key Specifications Table

      Description
      Catalogue NumberCHVE75TS3
      Trade Name
      • Millipore Express®
      DescriptionMillipore Express® SHR Cartridge Filter 5 in. 0.5/0.1 µm Code 7 Silicone
      References
      Product Information
      Device ConfigurationCartridge
      Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C. Reverse: 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
      Cartridge CodeCode 7
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      Key Applications
      • Sterile Filtration
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHR w/Prefilter
      Sterilization25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C and ≤ 0.35 bar (5) or 3 forward SIP cycles of 30 min @ 135 °C and 1 bar (15); 25 autoclave cycles of 60 min @ 126 °C
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.5 / 0.1 µm
      Air Diffusion at 23 °C≤12.8 mL/min @ 3.45 bar (50 psig) in water
      Bubble Point at 23 °C≥2586 mbar (37.5 psig) nitrogen with 70/30 % IPA/water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Differential PressureForward:
      100 psi (6.9 bar) at 25 °C
      25 psi (1.7 bar) at 80 °C
      15 psi (1.0 bar) at 135 °C

      Reverse:
      30 psi (2.1 bar) at 25 °C
      <1.0 psi (69 mbar) at 135 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 9.5 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length5 in. (12.5 cm)
      Diameter6.9 cm (2.7 in.)
      Filtration Area0.23 m²
      Device Size5 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

      Documentation

      Millipore Express® SHR Cartridge Filter 5 in. 0.5/0.1 µm Code 7 Silicone SDS

      Title

      Safety Data Sheet (SDS) 

      Certificates of Quality

      Title
      Millipore Express SHR W/Prefilter Cartridge C8AA26054
      Millipore Express SHR w/Prefilter Cartridge C7CA93905
      Millipore Express SHR w/Prefilter Cartridge C8EA61833Y
      Millipore Express SHR w/Prefilter Cartridge C8JA97158Y
      Millipore Express SHR w/Prefilter Cartridge C9SA86400Y
      Millipore Express SHR w/Prefilter Cartridge - C3MA29208
      Millipore Express SHR w/Prefilter Cartridge - C7HA15226
      Millipore Express SHR w/Prefilter Cartridge - C7KA50967
      Millipore Express SHR w/Prefilter Cartridge - C9SA55205Y
      Millipore Express SHR w/Prefilter Cartridge C4JA90567

      Technical Info

      Title
      Application Note: Performance of High-Area Millipore Express® Cartridge Filters
      Filter Integrity Test Methods
      Scalable Process Filtration with Millipore Express® SHR 0.1 μm Filters
      Steam-in-Place Method in the Reverse Direction for Millipore Express® PES Filters

      Data Sheet

      Title
      Millipore Express® SHR Hydrophilic Filters

      Posters

      Title
      Quality by Design (QbD) Principles in Aseptic Processing (EMD)

      User Guides

      Title
      Filters with Millipore Express® Membrane -Wetting Instructions, Integrity Testing and Drying Guidelines
      Vmax Constant Pressure