Our broad portfolio consists of multiplex panels that allow you to choose, within the panel, analytes that best meet your needs. On a separate tab you can choose the premixed cytokine format or a single plex kit.
Cell Signaling Kits & MAPmates™
Choose fixed kits that allow you to explore entire pathways or processes. Or design your own kits by choosing single plex MAPmates™, following the provided guidelines.
The following MAPmates™ should not be plexed together:
-MAPmates™ that require a different assay buffer
-Phospho-specific and total MAPmate™ pairs, e.g. total GSK3β and GSK3β (Ser 9)
-PanTyr and site-specific MAPmates™, e.g. Phospho-EGF Receptor and phospho-STAT1 (Tyr701)
-More than 1 phospho-MAPmate™ for a single target (Akt, STAT3)
-GAPDH and β-Tubulin cannot be plexed with kits or MAPmates™ containing panTyr
.
Catalog Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Select A Species, Panel Type, Kit or Sample Type
To begin designing your MILLIPLEX® MAP kit select a species, a panel type or kit of interest.
Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
If you have chosen panel analytes and then choose a premix or single plex kit, you will lose that customization.
Catalogue Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Species
Panel Type
Selected Kit
Qty
Catalog Number
Ordering Description
Qty/Pack
List Price
96-Well Plate
Qty
Catalog Number
Ordering Description
Qty/Pack
List Price
Add Additional Reagents (Buffer and Detection Kit is required for use with MAPmates)
Qty
Catalog Number
Ordering Description
Qty/Pack
List Price
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
This item has been added to favorites.
The Product Has Been Added To Your Cart
You can now customize another kit, choose a premixed kit, check out or close the ordering tool.
Durapore® Membrane Filters
Durapore® membranes made with Polyvinylidene fluoride (PVDF) provide high flow rates and throughput, low extractables and broad chemical compatibility.More
Durapore® membranes made with Polyvinylidene fluoride (PVDF) provide high flow rates and throughput, low extractables and broad chemical compatibility. Less
Colony filtration blot: a new screening method for soluble protein expression in Escherichia coli Tobias Cornvik, Sue-Li Dahlroth, Audur Magnusdottir, Maria Dolores Herman, Rosemarie Knaust, Monica Ekberg & Pär Nordlund Nature Methods, 2005 Jul:2(7):507-509
2005
A functional study on polymorphism of the ATP-binding Cassette transpoter ABCG2: Toshihisa Ishikawa,Biochem.J, 373, 767-774, 2003, internal ref ABC-02 Biochem.J, 373, 767-774, 2003, internal ref ABC-02
2003
Comparison of microporous membrane morphologies using confocal scanning laser microscopy Charcosset C (reprint), et al. Journal of membrane science. 2000. v168, n2, p53-62
2000
ATP/Mg2+-dependent Cardiac Transport system for Flutathione S-Conjugates Toshihisa Ishikawa,J.Biological Chemistry, 264:29, 17343-17348, 1989, internal ref ABC-01 J.Biological Chemistry, 264:29, 17343-17348, 1989, internal ref ABC-01
1989
FAQ
Question
Answer
How do I clear my Millipore filters?
It is possible to clear Millipore filters by choosing a clearing agent with the same refractive index as the membrane. This is called the PORE FILLING TECHNIQUE. Filters appear opaque because of the diffraction of light through the tortuous pores. Filling the pores with a liquid that has the same refractive index as the membrane (ex. xylene for MF filters) allows light to pass through the filter at a uniform speed thus rendering the filter transparent. This technique can be used for most membrane filters with a single refractive index. The refractive index for Durapore membrane is 1.42 and for MF membrane its 1.50.
Please note that this does not work for polycarbonate membranes because these membranes have more than one refractive index (1.62 and 1.58). If desired, the porous structure can be dissolved from Isopore polycarbonates by dissolving the filter in chloroform, methylene chloride or 1-methyl-2 pyrrolidone.
What is the blue separation paper between my filters?
It is a parchmentalized paper specially formulated for Millipore Corporation.
How do I tell the membrane from the separator?
The blue paper is the separator.
How do I assemble a diffusion chamber containing tissue for implantation?
Wet a single membrane filter (either GSWP 013 00 or HAWP 013 00) with Milli-Q water and blot it to absorbent paper to remove excess water.
Glue the filter to one side of a diffusion chamber ring without hole (catalog number PR00 014 00), using MF cement (catalog number XX70 000 00), and let dry.
Sterilize this assembly, along with another membrane filter of the same type, by exposure to ethylene oxide gas or ultraviolet light.
Moisten the half-completed chamber and the separate sterile filter with a sterile physiological solution, and aseptically place the tissue to be studied in the half-completed chamber assembly.
Glue the cover filter in place using sterile technique.
What are the dimensions and width of the grids on the Millipore 47mm gridded membranes?
The grids are 3.08mm x 3.08mm square. A grid line is 44um in width and there is are average of 169 gridded squares per filter. Please note however that the actual filtration area and therefore the total number of squares in that area is dependent on the filter holder. For filter holders with 9.6sq.cm of filtration area there are 100 squares available. For filter holders with 13.8 sq.cm of filtration area the number of available grids are approximately 140.
How do I assemble a diffusion chamber containing suspension cells for implantation?
Wet two membrane filters (either GSWP 013 00 or HAWP 013 00) with Milli-Q water and blot them to absorbent paper to remove excess water. Glue a moist filter to each side of the diffusion chamber ring with hole (catalog number PR00 014 01) using MF cement (catalog number XX70 000 00). Sterilize the dried diffusion chamber with ethylene oxide gas or ultraviolet light. After sterilization, inject the cells through the hole in the plastic ring, and plug the hole with the nylon thread which comes with the rings (catalog number PR00 000 00 if ordered separately).
Can Millipore filters remove mycoplasma from my solution?
Mycoplasma can be removed from solutions by using a 0.1 um pore size filter. For mycoplasma reduction the 0.1 um Durapore filter can be used. Its Millipore code is VV. A 0.1 um Express membrane can also be used for removal of mycoplasma. Its membrane code is VP. These membranes are available in a number of fabricated fiter devices. For help determining which device would be best for your solution, call Millipore Technical Services.
Are the pore sizes of your Durapore membranes uniform or asymmetric?
The surfaces of the Durapore membrane are symmetric, however, the actual pores are not straight-through holes but rather follow a torturous path.
Which membrane should I use to filter my solution?
For general filtration use MCE. When you are looking for the lowest protein binding membrane use Durapore. For speed, and when filtering serum solutions use Millipore Express.
I would like to use the Durapore membrane discs and am interested in knowing what is meant by average pore size?
Since the size and uniformity of the Durapore membrane is accurately controlled during manufacturing, it is possible to rate membranes as absolute filters based on the largest particle that can pass through the membrane. It is then possible to confirm the pore size rating of the membrane filter using a non-destructive integrity test referred to as the bubble point test. This test is based on the fact that liquid is held in the membrane pores by surface tension and that the minimum pressure required to force liquid from the capillary structure is directly related to the capillary diameter.
C7631Durapore® membranes made with Polyvinylidene fluoride (PVDF) provide high flow rates and throughput, low extractables and broad chemical compatibility.
Durapore® membranes provide high flow rates and throughput, low extractables and broad chemical compatibility. Hydrophlic Durapore® membrane binds far less protein than nylon, nitrocellulose, or PTFE membranes.
Features & Benefits
Available in several pore sizes (both hydrophilic and hydrophobic varieties) to suit your application needs
Durapore® membrane filters have very low protein binding to minimize interaction with your sample and maximize recovery
Product Performance
General Specifications
Color: white Surface: plain Thickness: 125 µm Sterilization: by autoclave (121 °C at 1 bar), EO or gamma Operating temperature: 85 °C max. Bacterial endotoxins: 0.5 EU/mL Gravimetric extractables: < 0.5%
Detailed Specifications
Applications
Filter Code1
Pore Size
Wettability
Bubble Point (psi)
Water Flow Rate2 (mL/min/cm²)
Typical Air Flow3 (L/min/cm²)
Protein Binding (µg/cm2)
0.1 µm pore size, hydrophilic PVDF, 13 mm membrane
VVLP
0.1 µm
Hydrophilic
≥75 psi, air with water
>4
-
4 µg/cm²
0.22 µm pore size, hydrophilic PVDF, 13 mm membrane
GVWP
0.22 µm
Hydrophilic
≥50 psi, air with water
>12
-
4 µg/cm²
0.45 µm pore size, hydrophilic PVDF, 13 mm membrane
HVLP
0.45 µm
Hydrophilic
≥22 psi, air with water
>34
-
4 µg/cm²
0.65 µm pore size, hydrophilic PVDF, 13 mm membrane
DVPP
0.65 µm
Hydrophilic
≥15 psi, air with water
>78
-
4 µg/cm²
Clarifying filtration of biological solutions, particle monitoring
SVLP
5.0 µm
Hydrophilic
≥3 psi, air with water
>208
-
4 µg/cm²
0.1 µm pore size, hydrophobic PVDF, 47 mm membrane
VVHP
0.1 µm
Hydrophobic
≥26 psi, air with methanol
-
0.9
150 µg/cm²
0.22 µm pore size, hydrophobic PVDF, 47 mm membrane
GVHP
0.22 µm
Hydrophobic
≥18 psi, air with methanol
-
1.7
150 µg/cm²
0.45 µm pore size, hydrophobic PVDF, 47 mm membrane
HVHP
0.45 µm
Hydrophobic
≥9 psi, air with methanol
-
4.9
150 µg/cm²
1Corresponds to first 4 digits of catalogue number. 2Water Flow Rate measured with 500 mL of water at 25 oC and 27.5 inHg vacuum through 47 mm disc. 3Air flow rate measured at 10 psi. Values represent typical performance and are not established specifications.