Millidisk® Hydrophilic Cartridges 0.1 µm Durapore® MembraneClear Sorting & Filtering Show Filter
Catalog NumberDescriptionPack Size
MCVL10S03Millidisk® Cartridge 10-stack 0.1 µm Hydrophilic 3 Show Pricing & Availability
MCVL20S03Millidisk® Cartridge 20-stack 0.1 µm Hydrophilic 3 Show Pricing & Availability
MCVL40S03Millidisk® Cartridge 40-stack 0.1 µm Hydrophilic 3 Show Pricing & Availability

Back To Top

Millidisk® Hydrophilic Cartridges 0.22 µm Durapore® MembraneClear Sorting & Filtering Show Filter
Catalog NumberDescriptionPack Size
MCGL10S03Millidisk® Cartridge 10-stack 0.22 µm Hydrophilic 3 Show Pricing & Availability
MCGL20S03Millidisk® Cartridge 20-stack 0.22 µm Hydrophilic 3 Show Pricing & Availability
MCGL30S03Millidisk® Cartridge 30-stack 0.22 µm Hydrophilic 3 Show Pricing & Availability
MCGL40S03Millidisk® Cartridge 40-stack 0.22 µm Hydrophilic 3 Show Pricing & Availability

Back To Top

Millidisk® Hydrophilic Cartridges 0.45 µm Durapore® MembraneClear Sorting & Filtering Show Filter
Catalog NumberDescriptionPack Size
MCHL10S03Millidisk® Cartridge 10-stack 0.45 µm Hydrophilic 3 Show Pricing & Availability
MCHL20S03Millidisk® Cartridge 20-stack 0.45 µm Hydrophilic 3 Show Pricing & Availability
MCHL30S03Millidisk® Cartridge 30-stack 0.45 µm Hydrophilic 3 Show Pricing & Availability
MCHL40S03Millidisk® Cartridge 40-stack 0.45 µm Hydrophilic 3 Show Pricing & Availability

Back To Top

Millidisk® Hydrophilic Cartridges 5.0 µm (Nominal) Durapore® MembraneClear Sorting & Filtering Show Filter
Catalog NumberDescriptionPack Size
MCSL10S02Millidisk® Cartridge 10-stack 5.0 µm Hydrophilic 2 Show Pricing & Availability
MCSL20S02Millidisk® Cartridge 20-stack 5.0 µm Hydrophilic 2 Show Pricing & Availability
MCSL30S01Millidisk® Cartridge 30-stack 5.0 µm Hydrophilic 1 Show Pricing & Availability
MCSL40S01Millidisk® Cartridge 40-stack 5.0 µm Hydrophilic 1 Show Pricing & Availability

Back To Top

Millidisk® Hydrophobic Cartridges 0.22 µm Durapore® MembraneClear Sorting & Filtering Show Filter
Catalog NumberDescriptionPack Size
MCGB20S02Millidisk® Cartridge 20-stack 0.22 µm hydrophobic 2 Show Pricing & Availability
MCGB30S01Millidisk® Cartridge 30-stack 0.22 µm hydrophobic 1 Show Pricing & Availability
MCGB10S02Millidisk® Cartridge 10-stack 0.22 µm hydrophobic 2 Show Pricing & Availability
MCGB40S01Millidisk® Cartridge 40-stack 0.22 µm hydrophobic 1 Show Pricing & Availability

Back To Top

Documentation

Material Qualification Dossier

TitleVersion
1.0

Quality Management Dossier (Open Access)

Title

Operational Excellence Dossier

Title

FAQ

QuestionAnswer
Why are there no diffusion specifications on my Millipak/Millidisk/4" Opticap?Diffusion testing is proportional to the overall effective filtration areas. On small area devices (less than 2000 cm2) the diffusion flow rate is relatively small. This small flow rate will be difficult to accurately measure and therefore only a bubble point specifications is provided.
What is the compatibility of Durapore with high pH solutions?The upper recommended pH limit for Durapore membranes is 10. At pH >10, the hydrophilization layer of the membrane may become subject to hydrolysis. The extent of hydrolysis is a function of time, temperature , concentration and time of exposure. Upon exposure to high pH, the hydrophylization layer can swell which could result in a loss of permeability or flux. The hydrolysis of the hydrophilic layer will also lead to increased extractables from the membrane.
What are Millipore's general recommendations for filtering high pH solutions?For applications involving pH > 10, Millipore recommends the use or our PES membranes Express SHF or Express SHC. For information on these filters :

Express SHF: http://www.millipore.com/catalogue.nsf/docs/C8873
Express SHC: http://www.millipore.com/catalogue.nsf/docs/C9146
How can I differentiate filter plugging due to air bubbles, particulates, surface tension, inappropriate filter size, etc.?Air locking will occur when filtration is initiated without adequate venting or when air bubbles become trapped in fluid lines. Air will pass easily through a dry hydrophillic or hydrophobic filter. However, when a filter is wet and air is applied to a surface, the air will remain until it is manually moved upstream by venting or until the bubble point of the filter is reached. Bubble point is defined as the pressure at which gas displaces liquid for the largest set of filter pores and is able to flow through the pores. Air locking reduces the effective filtration area of the filter and thus reduces the flow rate.

Surface tension refers to the strong cohesive forces present between molecules at the surface of a liquid. The higher the surface tension, the more force is required to force fluid through the membrane..

Innapropriate filter size will can cause a filter to plug prematurely. Filter pore size is chosen based on the application. If the application requires a sterile fluid, than a 0.22 micron membrane would be used for standard solutions that have bacterial bioburden. A 0.1 micron filter would be used for applications where mycoplasma is a concern. Where virus contamination is a concern, ultrafiltration would be required. The selection of a filter pore size that is smaller than that required for the application will cause a decrease in filter capacity and an increase in cost.