A part of MilliporeSigma

KGW1A3TTT1 | Opticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 1-1/2 in. TC

KGW1A3TTT1
1  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service

       

      Contact Customer Service

      Click To Print This Page

      Overview

      Replacement Information

      Key Specifications Table

      Description
      Catalogue NumberKGW1A3TTT1
      Trade Name
      • Opticap®
      DescriptionOpticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 1-1/2 in. TC
      References
      Product Information
      FormatTriple Layer
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)3.5 bar (50 psid) @ 25 °C
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Prefilter MaterialBorosilicate Glass Fiber (BGF)
      T-line/Gauge PortT-line
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaPolysep™ II
      Sterilization3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
      Physicochemical Information
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Gravimetric ExtractablesThe extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length30 in. (75 cm)
      Length87.1 cm (34.3 in.)
      Filtration Area1.26 m²
      Inlet to Outlet Width15.2 cm (6.0 in.)
      Device Size30 in.
      Inlet Connection Diameter1-1/2 in.
      Nominal Pore Size1.0 / 0.2 / 0.1 µm
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Mixed Cellulose Esters (MCE)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L

      Documentation

      SDS

      Title

      Safety Data Sheet (SDS) 

      Certificates of Quality

      Title
      Opticap XLT 30 Capsule Ploysep II Media - C3AA38374
      Opticap XLT 30 Capsule Polysep II Media C5PA82142
      Opticap XLT 30 Capsule Polysep II Media - C2PA15497
      Opticap XLT 30 Capsule Polysep II Media - C2PA95956
      Opticap XLT 30 Capsule Polysep II Media - C2SA18082
      Opticap XLT 30 Capsule Polysep II Media - C3AA23785
      Opticap XLT 30 Capsule Polysep II Media - C3CA81482
      Opticap XLT 30 Capsule Polysep II Media - C3NA41927
      Opticap XLT 30 Capsule Polysep II Media - C3PA70582
      Opticap XLT 30 Capsule Polysep II Media - C4AA06424
      Opticap XLT 30 Capsule Polysep II Media - C4BA23010
      Opticap XLT 30 Capsule Polysep II Media - C6CA27330
      Opticap XLT 30 Capsule Polysep II Media - C6HA68836
      Opticap XLT 30 Capsule Polysep II Media - C6JA75561
      Opticap XLT 30 Capsule Polysep II Media C4MA08488
      Opticap XLT 30 Capsule Polysep II Media C4MA18369
      Opticap XLT 30 Capsule Polysep II Media C4PA33543
      Opticap XLT 30 Capsule Polysep II Media C5AA52377
      Opticap XLT 30 Capsule Polysep II Media C5DA92305
      Opticap XLT 30 Capsule Polysep II Media C5JA32507
      Opticap XLT 30 Capsule Polysep II Media C5KA41108
      Opticap XLT 30 Capsule Polysep II Media C5SA95996
      Opticap XLT 30 Capsule Polysep II Media C5SA97077
      Opticap XLT 30 Capsule Polysep II Media C6AA00561
      Opticap XLT 30 Capsule Polysep II Media C6BA09216
      Opticap XLT 30 Capsule Polysep II Media C6EA44436
      Opticap XLT 30 Capsule Polysep II Media C6EA58735
      Opticap XLT 30 Capsule Polysep II Media C6KA84196
      Opticap XLT Capsule Filter with Polysep II Media - C2DA12096
      Opticap XLT Capsule Filter with Polysep II Media - C2EA17091
      Opticap XLT Capsule Filter with Polysep II Media - C2JA37295
      Opticap XLT Capsule Filter with Polysep II Media - C2MA55330
      Opticap® XLT 30 Capsule Polysep™ II Media C6DA44434
      Opticap® XLT 30 Capsule Polysep™ II Media C6HA68828
      Opticap® XLT 30 Capsule Polysep™ II Media - C4KA91732
      Opticap® XLT 30 Capsule Polysep™ II Media - C5EA14172
      Opticap® XLT 30 Capsule Polysep™ II Media - C2SA10012
      Opticap® XLT Capsule Filter with Polysep™ II Media - C1SA56393
      Opticap® XLT Capsule Filter with Polysep™ II Media - C2CA91347