101736 OSTEOMOLL®

101736
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service
      View Pricing & Availability

      Overview

      Replacement Information

      Pricing & Availability

      Catalog Number AvailabilityPackaging Qty/Pack Price Quantity
      1017361000
      Retrieving availability...
      Limited AvailabilityLimited Availability
      Stocked 
      Discontinued
      Limited Quantities Available
      Available
        Remaining : Will advise
          Remaining : Will advise
          Will advise
          Contact Customer Service
          Contact Customer Service

          Plastic bottle 1 l
          Retrieving price...
          Price could not be retrieved
          Minimum Quantity needs to be mulitiple of
          Upon Order Completion More Information
          You Saved ()
           
          Request Pricing
          1017362500
          Retrieving availability...
          Limited AvailabilityLimited Availability
          Stocked 
          Discontinued
          Limited Quantities Available
          Available
            Remaining : Will advise
              Remaining : Will advise
              Will advise
              Contact Customer Service
              Contact Customer Service

              Plastic bottle 2.5 l
              Retrieving price...
              Price could not be retrieved
              Minimum Quantity needs to be mulitiple of
              Upon Order Completion More Information
              You Saved ()
               
              Request Pricing
              Description
              Catalogue Number101736
              DescriptionOSTEOMOLL RAPID DECALCIFIER-SOLUTION FOR
              OverviewDecalcification is necessary for optical microscopic examinations of hard tissue in routine histological procedures. For the decalcification of sensitive, calcium-containing tissues, such as iliac crest biopsies, OSTEOSOFT® can be used. Its formulation is based on EDTA. Its pendant, OSTEOMOLL®, can be used for the decalcification of hard tissue such as teeth and bone as its formulation is based on formaldehyde and hydrochloric acid. Both solutions are color-coded, to distinguish them from each other, fixatives and solvents used in the histological laboratory. OSTEOSOFT® is color-coded yellow, OSTEOMOLL® is color-coded blue. Whereby OSTEOSOFT® preserves the antigen structures in the tissue, thus, an IHC analysis can be performed, OSTEOMOLL® will be used for tissues that are not destined for antibody analysis.
              Both decalcifiers can be used for clinical diagnostic purposes and in laboratory accreditation processes as they are certified and registered as IVD and CE product.
              References
              Product Information
              HS Code3822 00 00
              Applications
              ApplicationDecalcification solution for bone and hard tissues in histology
              Biological Information
              Physicochemical Information
              Density1.10 g/ml (20 °C)
              pH value<1 (H₂O, 20 °C)
              Dimensions
              Materials Information
              Toxicological Information
              Safety Information according to GHS
              Hazard Pictogram(s) Hazard Pictogram(s)
              Hazard Pictogram(s)
              Hazard Pictogram(s)
              Hazard Statement(s)H350: May cause cancer.
              H290: May be corrosive to metals.
              H302: Harmful if swallowed.
              H315: Causes skin irritation.
              H317: May cause an allergic skin reaction.
              H319: Causes serious eye irritation.
              H335: May cause respiratory irritation.
              H341: Suspected of causing genetic defects.
              Precautionary Statement(s)P201: Obtain special instructions before use.
              P280: Wear protective gloves.
              P302 + P352: IF ON SKIN: Wash with plenty of soap and water.
              P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
              P308 + P313: IF exposed or concerned: Get medical advice/ attention.
              Signal WordDanger
              Storage class6.1 D Non combustible, acute toxicity cat. 3 / toxic or substances with chronic effects
              WGKWGK 3 highly hazardous to water
              Disposal9
              Carcinogenic compounds and flammable compounds labelled "Highly toxic" or "Toxic": container F. Alkyl sulfates are carcinogenic; Take particular care to avoid inhalation and skin contact. To neutralize alkyl sulfates, add dropwise (from a dropping funnel) to concentrated ice-cool Ammonia solution (Cat.No. 105426) with vigorous stirring. Before placing in container D, check the pH with pH Universal indicator strips (Cat.No. 109535).
              Safety Information
              Hazard Symbols Hazard SymbolsToxic
              Categories of dangerharmful, irritant, carcinogenic, sensitizing
              R PhraseR 45-20/21/22-36/37/38-68-43
              May cause cancer.Also harmful by inhalation, in contact with skin and if swallowed.Irritating to eyes, respiratory system and skin.Possible risk of irreversible effects.May cause sensitisation by skin contact.
              S PhraseS 53-36/37-45
              Avoid exposure - obtain special instructions before use.Wear suitable protective clothing and gloves.In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
              Product Usage Statements
              Storage and Shipping Information
              StorageStore at +15°C to +25°C.
              Packaging Information
              Transport Information
              Declaration (railroad and road) ADR, RIDUN 1789 , 8, II
              Declaration (transport by air) IATA-DGRUN 1789 , 8, II
              Declaration (transport by sea) IMDG-CodeUN 1789 , 8, II, Segregation Group: 1 (Acids)
              Supplemental Information
              Specifications
              Performance testpasses test

              Related Products & Applications

              Accessories (Secondary)

              Catalog Number Description  
              109204 Giemsa's azur eosin methylene blue solution Show Pricing & Availability

              Related Products By: Application Facete

              Related Products By: Brand Facete

              Categories

              IVD/OEM Materials & Reagents > Microscopy > Universal Reagents > Decalcification
              IVD/OEM Materials & Reagents > Microscopy > Histology > Auxiliaries for Histology