A part of MilliporeSigma

CGEP03TE3 | Millipore Express® SHF Cartridge Filter 30 in. 0.2 µm Code 0 EPDM

3  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
Request Pricing
Limited AvailabilityLimited Availability
Limited Quantities Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service


      Contact Customer Service

      Click To Print This Page


      Replacement Information

      Key Specifications Table

      Catalogue NumberCGEP03TE3
      Trade Name
      • Millipore Express®
      DescriptionMillipore Express® SHF Cartridge Filter 30 in. 0.2 µm Code 0 EPDM
      Product Information
      Device ConfigurationCartridge
      Maximum Inlet Pressure, bar (psi)Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
      Cartridge CodeCode 0 (2-222) O-rings
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHF
      Sterilization25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      Physicochemical Information
      Pore Size0.2 µm
      Air Diffusion at 23 °C≤90 mL/min @ 2.75 bar (40 psig) in water
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Differential PressureForward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 30 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Cartridge Nominal Length30 in. (75 cm)
      Diameter6.9 cm (2.7 in.)
      Filtration Area1.62 m²
      Device Size30 in.
      Materials Information
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialEPDM
      Support MaterialPolypropylene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L




      Safety Data Sheet (SDS) 

      Certificates of Quality

      Millipore Express SHF Cartridge - SAMPLE1017

      Technical Info

      1X PBS (Phosphate Buffered Saline) Buffer Mixing Optimization (EMD)
      Application Note: Cellvento™ CHO-100 Media Mix and Filtration Optimization (EMD)
      Scalable Process Filtration with Millipore Express® SHF 0.2 μm Filters
      Steam-in-Place Method in the Reverse Direction for Millipore Express® PES Filters

      Data Sheet

      Millipore Express® SHF Hydrophilic Filters (EMD)


      Quality by Design (QbD) Principles in Aseptic Processing (EMD)

      User Guides

      Filters with Millipore Express® Membrane -Wetting Instructions, Integrity Testing and Drying Guidelines