      Replacement Information

      Key Specifications Table

      Catalogue NumberCGEP01TF3
      Trade Name
      • Millipore Express®
      DescriptionMillipore Express® SHF Cartridge Filter 10 in. 0.2 µm Code 0 Fluorocarbon
      Product Information
      Device ConfigurationCartridge
      Maximum Inlet Pressure, bar (psi)Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
      Cartridge CodeCode 0 (2-222) O-rings
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHF
      Sterilization25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      Physicochemical Information
      Pore Size0.2 µm
      Air Diffusion at 23 °C≤30 mL/min @ 2.75 bar (40 psig) in water
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Differential PressureForward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 10 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Cartridge Nominal Length10 in. (25 cm)
      Diameter6.9 cm (2.7 in.)
      Filtration Area0.54 m²
      Device Size10 in.
      Materials Information
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialFluorocarbon rubber
      Support MaterialPolypropylene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L


      Material Qualification Dossier




      Safety Data Sheet (SDS) 

      Certificates of Quality

      Milipore Express SHF Cartridge - C3MA18961
      Millipore Express SHF Cartridge - C2SA10555
      Millipore Express SHF Cartridge - C3BA40263
      Millipore Express SHF Cartridge - C3CA83763
      Millipore Express SHF Cartridge - C3DA87408
      Millipore Express SHF Cartridge - C3HA70136
      Millipore Express SHF Cartridge - C3KA96992
      Millipore Express SHF Cartridge - C3KA99587
      Millipore Express SHF Cartridge - C3PA63296
      Millipore Express SHF Cartridge - C4AA88480
      Millipore Express SHF Cartridge - C4BA11401
      Millipore Express SHF Cartridge - C4CA37702
      Millipore Express SHF Cartridge - C6CA43125
      Millipore Express SHF Cartridge - C6DA51064
      Millipore Express SHF Cartridge - C6HA84059
      Millipore Express SHF Cartridge C4SA45705
      Millipore Express SHF Cartridge C4SA51834
      Millipore Express SHF Cartridge C5CA86934
      Millipore Express SHF Cartridge C5MA61482
      Millipore Express SHF Cartridge C6EA64008
      Millipore Express SHF Cartridge C6HA70198
      Millipore Express SHF Cartridge C6MA15731
      Millipore Express SHF Hydrophilic Cartridge Filter - C0MA81097
      Millipore Express SHF Hydrophilic Cartridge Filter - C0NA88760
      Millipore Express SHF Hydrophilic Cartridge Filter - C1DA64586
      Millipore Express SHF Hydrophilic Cartridge Filter - C1HA86444
      Millipore Express SHF Hydrophilic Cartridge Filter - C1NA40203
      Millipore Express SHF Hydrophilic Cartridge Filter - C2MA52486
      Millipore Express SHF Hydrophilic Cartridge Filter - C2NA65386
      Millipore Express® SHF Cartridge - C3NA43347
      Millipore Express® SHF Cartridge - C4NA22578
      Millipore Express® SHF Hydrophilic Cartridge Filter - C0JA61950
      Millipore Express® SHF Hydrophilic Cartridge Filter - C1KA14253
      Millipore Express® SHF Hydrophilic Cartridge Filter - C2BA88301
      MilliporeExpress® SHF Hydrophilic Cartridge Filter - C1MA22349
      MilliporeExpress® SHF Hydrophilic Cartridge Filter - C1SA57198
      MilliporeExpress® SHF Hydrophilic Cartridge Filter - C2DA06601

      Technical Info

      1X PBS (Phosphate Buffered Saline) Buffer Mixing Optimization (EMD)
      Application Note: Cellvento™ CHO-100 Media Mix and Filtration Optimization (EMD)
      Scalable Process Filtration with Millipore Express® SHF 0.2 μm Filters
      Steam-in-Place Method in the Reverse Direction for Millipore Express® PES Filters

      Data Sheet

      Millipore Express® SHF Hydrophilic Filters (EMD)


      Quality by Design (QbD) Principles in Aseptic Processing (EMD)


      How is Durapore membrane different than Millipore Express SHF? Durapore membrane is made from a different polymer (polyvinylidene fluoride (PVDF) versus the polyethersulfone membrane of Millipore Express SHF) and has a different pore structure. These give Millipore SHF a flow advantage.
      How is the Millipore Express SHF membrane different than the Millipore Express and Express Plus membranes used for Life Science filtration? Millipore Express SHF was designed specifically for pharmaceutical applications, as a sterilizing grade, high flux, and caustic compatible membrane for large scale devices.

      Millipore Express and Express Plus membranes were designed for sterile filtration of tissue culture media and are not compatible with caustics. Millipore Express and Espress Plus are available only in laboratory scale devices.
      Are integrity tests are run on Millipore Express SHF cartridges prior to release? All Millipore Express SHF filters are 100% integrity tested prior to release.
      How do I integrity test this filter? For diffusion testing, cartridge integrity can be measured either: 1) .visually with a downstream mass flow monitor, or 2). with an inverted graduated cylinder, or 3). using an automated integrity tester. For bubble point testing, an enhanced bubble point test (diffusion test followed by a bubble point test) using an automated integrity tester is recommended.

      User Guides

      Filters with Millipore Express® Membrane -Wetting Instructions, Integrity Testing and Drying Guidelines