      Catalogue NumberCHGE75TF3
      Trade Name
      • Millipore Express®
      DescriptionMillipore Express® SHC Cartridge Filter 5 in. 0.5/0.2 µm Code 7 Fluorocarbon
      Product Information
      Device ConfigurationCartridge
      Maximum Inlet Pressure, bar (psi)Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 1.0 bar (15 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
      Cartridge CodeCode 7
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHC
      Sterilization25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C and 0.35 bar (5) or 3 forward SIP cycles of 30 min @ 135 °C and 1 bar (15 psid); 25 autoclave cycles of 60 min @ 126 °C
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      Physicochemical Information
      Pore Size0.5 / 0.2 µm
      Air Diffusion at 23 °C≤13.3 mL/min @ 2.75 bar (40 psig) in water
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Differential PressureForward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 9.5 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Cartridge Nominal Length5 in. (12.5 cm)
      Diameter6.9 cm (2.7 in.)
      Filtration Area0.23 m²
      Device Size5 in.
      Materials Information
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialFluorocarbon rubber
      Support MaterialPolypropylene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L


      Material Qualification Dossier




      Safety Data Sheet (SDS) 

      Certificates of Quality

      Millipore Express SHC Cartridge - SAMPLE1058
      Millipore Express® SHC Hydrophilic Cartridge Filter - C2AA74009

      Technical Info

      1X PBS (Phosphate Buffered Saline) Buffer Mixing Optimization (EMD)
      Application Note: Cellvento™ CHO-100 Media Mix and Filtration Optimization (EMD)
      Steam-in-Place Method in the Reverse Direction for Millipore Express® PES Filters

      Data Sheet

      Millipore Express® SHC Hydrophilic Filters


      Quality by Design (QbD) Principles in Aseptic Processing (EMD)

      User Guides

      Filters with Millipore Express® Membrane -Wetting Instructions, Integrity Testing and Drying Guidelines
      Vmax Constant Pressure