FCCS025210 FlowCellect™ PI3K-mTOR Signaling Cascade kit

FCCS025210
25 Tests / Kit  
Retrieving price...
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Click To Print This Page

      Overview

      Replacement Information
      Description
      Catalogue NumberFCCS025210
      Trade Name
      • FlowCellect
      DescriptionFlowCellect™ PI3K-mTOR Signaling Cascade kit
      OverviewSignaling through the PI3K/Akt/mTOR pathway is constitutively active in many cancer cells due to the loss of PTEN (tumor suppressor), exposure to carcinogens, activation of growth receptors, as well as mutations or amplifications of PI3K or Akt. The relevance of this pathway in difficult to treat cancers makes theses signaling nodes prime targets in advancing anticancer therapies.

      Millipore’s FlowCellect™ PI3K-mTOR Analysis Kit includes two directly conjugated phospho-specific signaling antibodies which are optimized for multi-color flow cytometry applications to analyze the mTOR pathway in great detail. The phosphorylation of Akt is indicative of the upstream PI3K signaling, marking the cells initiation into proliferation or cell survival. Phosporylated-Ribosomal S6 protein is indicative of downstream mTOR and p70S6K signaling leading to protein translation.

      By providing both of these antibodies in one kit, the researcher has the complete solution when examining the mTOR pathway which is beneficial for the elucidation of drug effectiveness in their cancer research.
      Alternate Names
      • Flow Cellect
      Background InformationExamination of cell signaling pathways and monitoring their activation status have been extremely important for researchers to understand the detailed mechanisms of cellular functions and the cause of various diseases. Many signal transduction pathways have been implicated to lead to multiple outcomes such as apoptosis, cell differentiation, cell growth and cell proliferation, all of which have been extensively studied for the treatment of various cancers and autoimmune diseases.

      The study of cell signaling pathways are now made easier with the use of activation status-specific and phospho-specific antibodies. Measurement of protein phosphorylation with phospho-specific antibodies has given insight into kinase signaling cascades [Krutzik, P.O. et al. (2003]. Multi-parameter phospho flow cytometry is a powerful tool for studying multiple pathways in a mixed cell population at the same time.

      Millipore offers a range of novel antibody based multi-parameter FlowCellect™ kits which are specifically designed to address the current needs in phospho flow cytometry analysis of cell signaling pathways and cancer research in a multi-parametric fashion. All of the antibodies provided in the kit have been directly conjugated and optimized for multi-color flow cytometry applications. By using a combination of antibodies provided in the kit, researchers can now accurately measure key signaling nodes and end points activations. Moreover, researchers can also dissect any particular linear signaling pathway cascade by measuring the activation of several components in a time course dependent manner. By using the FlowCellect™ PI3K-mTOR Signaling Cascade kit, the researcher can now study mTOR in greater detail and its relationship in general cell function such as cell proliferation, apoptosis and cancer.

      All FlowCellect™ kits are optimized on the bench-top Guava® flow cytometry systems, which saves valuable time and sample volume. All kits contain optimized fixation, permeabilization, wash and flow buffers to provide researchers with a complete solution for simultaneous detection of multiple pathway activations. With the Guava platform and FlowCellect™ kits, one can finally have an easy, reliable and fully validated solution to study the complex cell signaling pathways right in the comfort of your own lab.
      References
      Product Information
      Components
      • 1. 20X Anti-phospho-Ribosomal Protein S6 (Ser235) PerCP conjugate Monoclonal Antibody: (Part No. CS203308) One 150 µL vial
      • 2. 20X Anti-phospho-Akt1/PKBα (Ser473) Alexa Fluor 488 conjugate Monoclonal Antibody: (Part No. CS203310) One 150 µL vial
      • 3. Fixation Buffer: (Part No. CS202122) One 13 mL bottle
      • 4. 10X Wash Buffer: (Part No. CS202123) One 13 mL bottle
      • 5. 5X Assay Buffer: (Part No. CS202124) One 55 mL bottle
      • 6. 1X Permeabilization Buffer: (Part No. CS203284) Two 13 mL bottles
      Detection method125I Fluorescent
      Applications
      ApplicationThis FlowCellect PI3K-mTOR Analysis Kit includes two directly conjugated phospho-specific signaling antibodies which are optimized for multi-color flow cytometry applications to analyze the mTOR pathway in great detail.
      Key Applications
      • Flow Cytometry
      Biological Information
      HostRabbit/Murine
      Species Reactivity
      • Human
      Antibody TypeMonoclonal Antibody
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Quality AssuranceLot to lot in-process testing on all kit components
      Usage Statement
      • Alexa Fluor® is a registered trademark of Molecular Probes, Inc.
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage Conditions4-8°C for antibodies and buffers
      Packaging Information
      Material Size25 Tests / Kit
      Transport Information
      Supplemental Information
      Specifications

      Related Products & Applications

      Product Families

      Related Products By: Brand Facete

      Categories

      Life Science Research > Cell Analysis > guava easyCyte Flow Cytometers > Flow Cytometry Kits & Reagents