      Overview

      Replacement Information

      Key Specifications Table

      Description
      Catalogue NumberCS60HX01F1
      Trade Name
      • Clarisolve®
      DescriptionClarisolve® 60 µm Pod Depth Filters, 0.11 m2 (1.18 ft2)
      References
      Product Information
      Device ConfigurationPod
      Filter Grade60HX
      Maximum Differential Pressure, bar (psid)Maximum: 3.5 bar (50 psid) @ ≤ 25 °C or 1.0 bar (15 psid) @ ≤ 80 °C; Forward: 2.1 bar (30 psid) @ ≤ 25 °C or 1.0 bar (15 psid) @ ≤ 80 °C; Reverse: 2.1 bar (30 psid) @ 25 °C
      Applications
      ApplicationHigh-density cell cultures
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
      SterilizationIntegrity is maintained after 1 autoclave cycle of 60 minutes at 123 °C.
      Physicochemical Information
      Product Water Conductivity at 25°C≤ 0.15 µS/cm post autoclave (1 cycle of 60 minutes at 123 °C) and flushed at a flux rate of 600 LMH pure water flush for 10 minutes. A sample of filtrate was pulled every 2 minutes during flush and tested for conductivity.
      Dimensions
      Height32 cm (12.5 in.)
      Width3.0 cm (1.2 in.)
      Length62 cm (24.2 in.)
      Filtration Area0.11 m²
      Materials Information
      Chemistry
      • Polypropylene (PP)
      Device Material
      • Polypropylene
      Materials of ConstructionPolypropylene (PP)
      Seal MaterialThermo Plastic Elastomer (TPE)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Transport Information
      Supplemental Information
      Specifications
      Metals
      • Per 24-hour static soak in 10 liters pure water post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of surface area:
        Aluminum (AI): ≤ 0.183 mg/ft2
        Antimony (Sb): < 0.001 mg/ft2
        Arsenic (As): below detectable limits
        Barium (Ba): ≤ 0.108 mg/ft2
        Bismuth (Bi): below detectable limits
        Boron (B): ≤ 0.022 mg/ft2
        Cadmium (Cd): below detectable limits
        Calcium (Ca): ≤ 0.364 mg/ft2
        Chromium (Cr): 0.000 mg/ft2
        Cobalt (Co): below detectable limits
        Copper (Cu): ≤ 0.004 mg/ft2
        Gallium (Ga): 0.000 mg/ft2
        Germanium (Ge): below detectable limits
        Iron (Fe): ≤ 0.003 mg/ft2
        Lead (Pb): below detectable limits
        Lithium (Li): 0.000 mg/ft2
        Magnesium (Mg): ≤ 0.213 mg/ft2
        Manganese (Mn): below detectable limits
        Mercury (Hg): below detectable limits
        Molybdenum (Mo): < 0.001 mg/ft2
        Nickel (Ni): 0.000 mg/ft2
        Potassium (K): ≤ 0.671 mg/ft2
        Silver (Ag): below detectable limits
        Sodium (Na): ≤ 21.0 mg/ft2
        Strontium (Sr): ≤ 0.002 mg/ft2
        Tin (Sn): 0.000 mg/ft2
        Titanium (Ti): ≤ 0.004 mg/ft2
        Tungsten (W): 0.000 mg/ft2
        Vanadium (V): 0.000 mg/ft2
        Zinc (Zn): below detectable limits
      TOCMeasured at below detectable limits.