A part of MilliporeSigma

CTGR04TP1 | Aervent CTGR Cartridge Filter 40 in. 0.2 µm Code 0

CTGR04TP1
1  Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service

       

      Contact Customer Service

      Click To Print This Page

      Overview

      Replacement Information

      Key Specifications Table

      Description
      Catalogue NumberCTGR04TP1
      Trade Name
      • Aervent®
      DescriptionAervent CTGR Cartridge Filter 40 in. 0.2 µm Code 0
      References
      Product Information
      Device ConfigurationCartridge
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
      Maximum Inlet Pressure, bar (psi)Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
      Cartridge CodeCode 0 (2-222) O-rings
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaAervent®
      Sterilization150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophobic
      Physicochemical Information
      Pore Size0.2 µm
      Bubble Point at 23 °C≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
      Gravimetric ExtractablesThe extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
      HydroCorr≤0.75 mL/min @ 2.6 bar (38 psig)
      Nitrogen Diffusion at 23 °C≤96 mL/min @ 965 mbar (14 psig) in 70/30 % IPA/water
      Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length40 in. (100 cm)
      Diameter6.9 cm (2.7 in.)
      Filtration Area2.6 m²
      Device Size40 in.
      Materials Information
      Chemistry
      • Polytetrafluoroethylene (PTFE)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageEasy-Open bag
      Transport Information
      Supplemental Information
      Specifications

      Related Products & Applications

      Product Families

      Related Products By: Brand Facete

      Categories

      Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Gas > Aervent