Elix Gulfstream Clinical Water purification systems

Ideal all-in-one solution for high-volume clinical analyzers

Related Resources

Elix Gulfstream Clinical Systems

Overview

Specifications

Ordering Information

Water Systems Clear Sorting & Filtering
Catalog Numbericon Descriptionicon Pack Sizeicon
ZWGSC5035Elix® Gulfstream Clinical 35 Water Purification System (230V)1 Show Pricing & Availability
ZWGSC5070Elix® Gulfstream Clinical 70 Water Purification System (230V)1 Show Pricing & Availability
ZWGSC5100Elix® Gulfstream Clinical 100 Water Purification System (230V)1 Show Pricing & Availability
ZWGSC6035Elix® Gulfstream Clinical 35 Water Purification System (120V)1 Show Pricing & Availability
ZWGSC6070Elix® Gulfstream Clinical 70 Water Purification System (120V)1 Show Pricing & Availability
ZWGSC6100Elix® Gulfstream Clinical 100 Water Purification System (120V)1 Show Pricing & Availability

Back To Top

Consumables Clear Sorting & Filtering
Catalog Numbericon Descriptionicon Pack Sizeicon
5874316024Sanitization Tablets (US)24 Show Pricing & Availability
CDUFBC001Biopak® Clinical Cartridge1 Show Pricing & Availability
PR0GTL0S1Progard® TL1 Pretreatment Pack1 Show Pricing & Availability
PR0GTL0S1USProgard® TL1 Pretreatment Pack (US)1 Show Pricing & Availability
PR0GTLCS1Progard® TL1 Cl2 Autoclean Pretreatment Pack1 Show Pricing & Availability
PRPK0L0S1PrePak L1 Pretreatment Pack1 Show Pricing & Availability
PRPK0L0S1USPrePak L1 Pretreatment Pack (US)1 Show Pricing & Availability
QGARDTL01Q-Gard® TL Polishing Cartridge1 Show Pricing & Availability
TANKMPK01Vent Filter for PE Tank (Type 2 Water)1 Show Pricing & Availability
ZLXUVLPL1UV Lamp1 Show Pricing & Availability
ZWACID012ROClean A Acid Cleaning Pouch12 Show Pricing & Availability
ZWBASE012ROClean B Base Cleaning Pouch12 Show Pricing & Availability
ZWCL01F50Sanitization Tablets45 Show Pricing & Availability

Back To Top

    Documentation

    Brochure

    Title
    Elix Gulfstream Clinical Water Purification System

    References | 15 Available | See All References

    Reference overviewPub Med ID
    Designing a customized lab water system
    J. Denoncourt
    Laboratory Design newsletter (2010) 15 (10) 2010

    Show Abstract Full Text Article
    The impact of water quality on IVD testing
    J. Long and S. Mabic
    IVD Technology (2009), June, p. 29 2009

    Show Abstract Full Text Article
    Trace Analysis of Perchlorate: Analytical Method and Removal Efficiency of Purification Technologies
    E. Castillo, E. Riché, I. Kano and S. Mabic
    LCGC "The Peak" (2008) August, 21-30. 2008

    Show Abstract Full Text Article
    The Importance of Water Quality in the Histology Laboratory
    E Riché, E Macrea, W Lange, S Mabic
    HistoLogic (2008) XLI(2), 21-26 2008

    Show Abstract Full Text Article
    Water quality in patient testing
    J. Long and S. Mabic
    Clinical Lab Products (2007) April, 22-23 2007

    Show Abstract Full Text Article
    Benefits of the pretreatment step in purifying water for LC-MS analyses
    C. Regnault, S. Mabic
    LC-GC The Column Vol 1 issue 9 12-15 2005

    Show Abstract
    New approach to calibrating conductivity meters in the low conductivity range
    P. Spitzer, B. Rossi, Y. Gaignet, S. Mabic, U. Sudmeier
    Accred. Qual. Assur. 10 78-81 2005

    Show Abstract
    Using ultrapure water in ion chromatography to run analyses at the ng/L level
    I. Kano, E. Castillo, D. Darbouret and S. Mabic
    Journal of Chromatography A (2004) 1039, 27-31 2004

    Show Abstract
    Qualification of an electro-deionization module via experimental design and ion chromatographic studies
    E. Castillo, D. E. Coleman, D. Darbouret, T. Dimitrakopoulos, E. Feuillas, L. E. Vanatta
    Journal of Chromatography A 1039 63-70 2004

    Show Abstract
    A total water purification system
    J. Denoncourt
    BioPharm International, August 2004: 22-24 2004

    Show Abstract Full Text Article

    C100631Ideal all-in-one solution for high-volume clinical analyzers

    With its purification technologies, system reservoir and pumps all contained within the system cabinet, the Elix Gulfstream Clinical water purification system is an ideal all-in-one solution for high-volume clinical analyzers. Designed to provide up to 100 LPH and 2000 L daily, this system produces constant quality clinical laboratory reagent water (CLRW) to feed clinical analyzers. Integrated Elix technology and improved reverse osmosis cartridges ensure reduced running costs and eliminate downtime.

    The system’s small footprint, with everything needed for operation pre-installed in or on the cabinet, enables fast installation in confined spaces, with external tubing kept to a minimum. No bench space is required, and there are no components that require wall-mounting. Wheels on the cabinet base allow the system to be moved easily, either to feed another analyzer, or to accommodate lab cleaning when necessary.

    The system is designed to provide pure water that meets Clinical and Laboratory Standards Institute (CLSI) clinical laboratory reagent water (CLRW) standards, and is RoHS compliant.

    • Produces water with flow rates of 35, 70 and 100 L/h, up to 2000 L daily.
    • Integrates patented, proven Elix electrodeionization (EDI) technology
    • No softeners or conditioning cartridges needed prior to the Elix module
    • All systems components in a single, small footprint cabinet
    • Designed to be in compliance with CLSI® CLRW quantitative specifications.

    Features

    • “All-in-one” solution on wheels saves space, allows easy installation and mobility
    • Elix technology / improved RO cartridges help reduce running costs and eliminate downtime
    • Provides consistent water quality
    • Keeps bacterial levels under control
    • Meets today’s increased water and environmental standards

    Quality of Water Distributed to the Analyzer
    Resistivity > 10 MΩ.cm (CO₂ is < 30 ppm)
    Conductivity < 0.1 µS / cm (CO₂ is < 30 ppm)
    Microorganisms < 10 cfu/ml (immediately after the final filter)
    Max. dispense flow at 1 bar (15 psi) 2.4 LPM
    Max. dispense flow at 2 bar (30 psi) 1.8 to 2 LPM
    Quality of Water Distributed to the Reservoir
    Elix water flow rate* Elix water quality feeding the reservoir
    Elix Gulfstream Clinical 35 35 LPH >5 MΩ.cm @ 25 °C (Typically 10–15 MΩ.cm**)
    Elix Gulfstream Clinical 70 70 LPH >5 MΩ.cm @ 25 °C (Typically 10–15 MΩ.cm**)
    Elix Gulfstream Clinical 100 100 LPH >5 MΩ.cm @ 25 °C (Typically 10–15 MΩ.cm**)
    * Nominal flow from 7–30 °C
    ** When CO2 is < 30 ppm in the feed water
    Feed Water Specifications
    Feed water quality Potable tap water feed
    Feed water conductivity < 2000 µS/cm at 25 °C
    Feed water temperature 5 to 35 °C
    Pressure 2 to 6 bar
    Maximum LSI +0.3
    pH 4 to 10
    General System Information
    Approximate Operating Weight (with full tank) Dimensions
    Elix Gulfstream Clinical 35 239 kg (527 lb) Height – 1528 mm (60 in)
    Width – 492 mm (19.4 in)
    Depth – 852 mm (33.5 in)***
    Elix Gulfstream Clinical 70 248 kg (547 lb) Height – 1528 mm (60 in)
    Width – 492 mm (19.4 in)
    Depth – 852 mm (33.5 in)***
    Elix Gulfstream Clinical 100 257 kg (567 lb) Height – 1528 mm (60 in)
    Width – 492 mm (19.4 in)
    Depth – 852 mm (33.5 in)***
    *** The tubing protection at the back of the system adds 100 mm to the depth.