KTGRA04TT3 Opticap XL capsule with Aervent filter, 0.2 µm

KTGRA04TT3
3  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
Stocked 
Discontinued
Limited Quantities Available
Available
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information

      Key Specifications Table

      Description
      Catalogue NumberKTGRA04TT3
      ReplacesKTGR04TC3
      Trade Name
      • Opticap®
      DescriptionOpticap XL capsule with Aervent filter, 0.2 µm
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 4.1 bar (60 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Applications
      Biological Information
      MediaAervent®
      Sterilization30 autoclave cycles of 30 min @ 135 °C; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophobic
      Physicochemical Information
      Pore Size0.2 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Bubble Point at 23 °C≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
      Gravimetric ExtractablesThe extractables level was equal to or less than 15 mg after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
      HydroCorr≤0.25 mL/min @ 2.6 bar (38 psig)
      Nitrogen Diffusion at 23 °C≤9 mL/min @ 965 mbar (14 psig) in 70/30 % IPA/water
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length7.7 in. (19.6 cm)
      Length19.6 cm (7.7 in.)
      Diameter8.4 cm (3.3 in.)
      Filtration Area0.21 m²
      Inlet to Outlet Width19.6 cm (7.7 in.)
      Device Size4 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polytetrafluoroethylene (PTFE)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications

      Documentation

      Opticap XL capsule with Aervent filter, 0.2 µm SDS

      Title

      Safety Data Sheet (SDS) 

      Certificates of Quality

      Title
      KTGRA04TT3 - C3AA17678
      KTGRA04TT3 - C3BA44525
      KTGRA04TT3 - C3BA50114
      KTGRA04TT3 - C3DA04427
      Optical XL 4 Capsule Aervent Membrane - C3CA92872
      Opticap XL 4 Aervent Membrane C9JA40883
      Opticap XL 4 Aervent Membrane C9JA69916
      Opticap XL 4 Aervent Membrane C9KA69286R
      Opticap XL 4 Capsule Aerent Membrane - C6SA48501
      Opticap XL 4 Capsule Aerent Membrane - C7KA47749

      Technical Info

      Title
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
      Bubble Point Test Method Using Aervent 0.2 µm Hydrophobic Membrane with 60/40 IPA
      Filter Integrity Test Methods

      User Guides

      Title
      Opticap® XL Capsules and Opticap® XLT Capsules

      Related Products & Applications

      Alternative Format

      Catalog Number Description  
      ATBCSEV01 M Air T Sieve for Cone Adapter Show Pricing & Availability
      ATBFEET01 M Air T Isolator Tripod Show Pricing & Availability
      ATBHC0N01 M Air T Cone Adapter Show Pricing & Availability
      ATBHPRE01 M Air T Pressure Reducer Show Pricing & Availability
      ATBPUMP01 M Air T Isolator Pump Show Pricing & Availability
      ATBTUBE01 M Air T Isolator Tubing 3 m Show Pricing & Availability
      FTPF00788 4 in. Tri-Clover clamp Show Pricing & Availability
      FTPF00789 Silicone 4 in. Tri-Clover gasket 1-cartridge housing Show Pricing & Availability
      YY2004045 Clamp 1 1/2 in. TC Show Pricing & Availability
      YY2004055 1 1/2 in. TC silicone gasket Show Pricing & Availability

      Product Families

      Related Products By: Brand Facete

      Categories

      Industrial Microbiology > Environmental Monitoring > Environmental Monitoring for Pharmaceutical & Cosmetics Industry > Active Air Monitoring Systems > M Air T > M Air T Isolator
      Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Gas > Aervent